Lack understanding and accountability
Ipsum Renewables review It came as a surprise to us that Ipsum Renewables have no bad reviews. Our experience has been very different. We had a whole retrofit to a 40 year old house replacing electric storage radiators with a Vaillant ASHP, 17 radiators and associated pipework. In our opinion they lacked understanding and knowledge of the system they fitted, failed to commission the system correctly which was signed off by an engineer not on site. After weeks of not getting the system working correctly including 3 occasions when the system totally failed (including Christmas Day) we felt we had no choice but to approach the manufacturer Vaillant who on each contact immediately identified and rectified the faults that Ipsum failed to recognise. There were many faults the main ones being (1) an over pressurised expansion vessel which likely led to the ASHP stopping on Christmas Day, 16 days after installation and never attended or acknowledged as a problem (2) failure to adequately insulate external pipework (in breach of Part L Building regs) which blew the AFVs when outdoor temperature fell to 3°C. We (and Severn Trent!) were repeatedly blamed for the problems in the system or that it was normal to experience what we were reporting. (3) Fitting the wrong PRV resulting in an intolerably noisy heating system and on the same site visit made the radiator balance worse than it was. Ipsum’s attitude and response was at times poor and extremely confrontational when meeting one of their owners face to face, where they refused to take any responsibility for the multiple errors and failures which we conclude is a result of their very poor understanding of how a Vaillant ASHP works and what can cause problems. Response to Ipsum's reply: Ipsum continue to show a persistent lack of accountability. Issues are from the failure to commission the whole heating & hot water installation correctly. Signed off by a senior engineer not on site. 3.5 months later, we are still experiencing installation issues. Faults that led to the 3 ASHP failures were: over pressurised expansion vessel, inadequate external insulation. Faults identified & confirmed in reports by Vaillant site visits. Reduced mains pressure & flow rate following installation, due to Ipsum’s failure to replace the obviously rusty faulty mains water inlet PRV, not due to Severn Trent as they claimed We had rapid email responses but NO site visits following reports of ASHP stopping - 1st on Christmas day no support for 9 days, then email response, ‘as it hasn’t reoccurred’ it must be ok. 2nd failure response, ‘we’ll monitor the data’ despite needing to repressurise every 6/8 days. Considered ‘normal’ or ‘bedding in’. 3rd failure response(AFVs opened when outdoor temp fell to 3°C). Said, not possible, data from sensors showed temp of 14/15°C, they were insidethe insulated ASHP. Badly insulated external pipework & AFVs exposed to outside temps, open at 3°C. Confirmed by Vaillant site visit. ASHP issues were NOT identified by Ipsum. No useful involvement by Ipsum with us or Vaillant as claimed. We independently approached Vaillant, they identified the causes of system failure & attended within 24 hours.Vaillant site visits identified & confirmed system faults indicated in data. We maintain Ipsum had a poor understanding of the ASHP they installed & lacked care and attention in the commissioning process. Video with sound is our heating system following Ipsum site visit, fitted wrong mains water inlet PRV & attempted to balance 17 radiators with a spanner, it didn’t go well. We complained by email, it was fixed, we were ‘told off’ in an extremely confrontational manner in our home for complaining by an owner Director as 'it was a 'family business’ Positives: reception, project manager,installers & one of the two owner directors have always been friendly, helpful & respectful. Heating pipework and electrical wiring installation was very good. In our opinion Ipsum senior engineers/owners let themselves and their staff down Mistakes can be made, all that was needed was acknowledgement and apology. They have so much to learn!